Estudio documental sobre la influencia del mantenimiento preventivo en la nitidez de las imágenes diagnósticas en equipos de rayos X.

dc.contributor.authorAlvarado, Paola
dc.contributor.authorCamacho, Elías
dc.contributor.authorCastillo, Joaquín
dc.contributor.authorPimentel, Eynar
dc.contributor.authorVillarreal, Juan (Director del trabajo)
dc.contributor.authorCarrillo, Margot (Asesora metodológica)
dc.date.accessioned2026-04-24T19:39:51Z
dc.date.issued2026-02
dc.descriptionTrabajo de grado para optar por el título de Licenciatura en Radiología e Imágenes Diagnósticas
dc.description.abstractEl presente estudio analiza la influencia del mantenimiento preventivo en la nitidez de las imágenes diagnósticas generadas por equipos de rayos X convencionales, aspecto fundamental para garantizar diagnósticos precisos y la seguridad del paciente. El objetivo general de la investigación fue analizar la evidencia científica disponible sobre la relación entre el mantenimiento preventivo y la calidad de las imágenes radiográficas en equipos de rayos X. La investigación se desarrolló bajo un enfoque cualitativo de tipo documental, mediante la revisión sistemática de literatura científica, normativas internacionales, guías técnicas y documentos institucionales relacionados con la radiología diagnóstica y el control de calidad en equipos radiológicos. Para el análisis se revisaron 20 documentos científicos y técnicos publicados entre los años 2007 y 2023, provenientes de organismos internacionales y literatura especializada en radiología. El proceso de análisis se realizó mediante categorización temática y comparación documental, permitiendo identificar los principales factores técnicos asociados con la nitidez de las imágenes radiográficas. Los resultados evidencian que la aplicación sistemática de programas de mantenimiento preventivo y control de calidad contribuye significativamente a mantener la estabilidad de los parámetros técnicos del equipo, tales como el kilovoltaje (kVp), el mili amperaje (mA) y el tiempo de exposición, factores que influyen directamente en la nitidez de la imagen diagnóstica. Asimismo, se identificó que la ausencia de mantenimiento preventivo incrementa la repetición de estudios radiográficos, favorece la aparición de artefactos en la imagen y aumenta innecesariamente la dosis de radiación al paciente. Se concluye que el mantenimiento preventivo constituye un elemento esencial para garantizar la calidad diagnóstica de las imágenes radiológicas, optimizar la seguridad radiológica y fortalecer la eficiencia operativa de los servicios de imagenología. En este sentido, se destaca la importancia de implementar programas estructurados de mantenimiento y control de calidad que aseguren el adecuado funcionamiento de los equipos de rayos X y la obtención de imágenes diagnósticas nítidas y confiables. Abstract This study analyzes the influence of preventive maintenance on the sharpness of diagnostic images produced by conventional X-ray equipment, a fundamental aspect to ensure accurate diagnoses and patient safety. The main objective of this research was to analyze the available scientific evidence regarding the relationship between preventive maintenance and the quality of radiographic images in X-ray equipment. The research was conducted using a qualitative documentary approach, through a systematic review of scientific literature, international regulations, technical guidelines, and institutional documents related to diagnostic radiology and quality control in radiological equipment. For the analysis, 20 scientific and technical documents published between 2007 and 2023 were reviewed, including publications from international organizations and specialized radiology literature. The analysis process was carried out through thematic categorization and documentary comparison, allowing the identification of the main technical factors associated with the sharpness of radiographic images. The results show that the systematic implementation of preventive maintenance and quality control programs significantly contributes to maintaining the stability of technical parameters of the equipment, such as kilovoltage (kVp), milliampere (mA), and exposure time, which directly influence the sharpness of diagnostic images. Likewise, the absence of preventive maintenance increases the repetition of radiographic studies, promotes the appearance of image artifacts, and unnecessarily increases the radiation dose to the patient. It is concluded that preventive maintenance is an essential element to guarantee the diagnostic quality of radiological images, optimize radiation safety, and strengthen the operational efficiency of imaging services. In this regard, the importance of implementing structured maintenance and quality control programs that ensure the proper functioning of X-ray equipment and the acquisition of sharp and reliable diagnostic images is highlighted.
dc.identifier.urihttps://repositorio.usantander.edu.pa/handle/123456789/135
dc.language.isoes
dc.relation.ispartofseriesT-122
dc.titleEstudio documental sobre la influencia del mantenimiento preventivo en la nitidez de las imágenes diagnósticas en equipos de rayos X.
dc.typeThesis

Files

Original bundle

Now showing 1 - 5 of 5
No Thumbnail Available
Name:
ESTRUCTURA DEL TRABAJO DE INVESTIGACIÓN COMO OPCIÓN A GRADO.pdf
Size:
2.42 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
FR-VIE-03_Cesin_de_derechos_de_autor Elias Camacho.pdf
Size:
262.08 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
FR-VIE-03_Cesin_de_derechos_de_autor Eynar Pimentel.pdf
Size:
264.6 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
FR-VIE-03_Cesin_de_derechos_de_autor Joaquin Castillo.pdf
Size:
261.25 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
FR-VIE-03_Cesin_de_derechos_de_autor Paola Alvarado.pdf
Size:
261.15 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: